Installation Guidelines for Stationary Compactors
The information contained below is a simplified interpretation of parts of the American National Standard Institute, ANSI-Z245.2-1997, Safety Standards for Stationary Compactors. A copy of this standard is available upon request and should be the primary reference for all safety issues.
Mark-Costello supplies this information only as an aid for understanding the installation section of the standard. Mark-Costello assumes no responsibility for any errors or omissions concerning this material. If you have any questions about the operation or installation of a Mark-Costello compactor, please contact our Customer Service Department at 1-(562) 630-7950
- Ground Feed Installation
- Cart Dumper Installation
- Thru-The-Wall Installation
- Location of Emergency Stop
- Dock Installation
- Location of Fused Disconnect
- Walk-On / Drive-On Installation
- Hand & Toe Rail Design
- Installer Labeling Requirements
Ground Feed Installation
If the charge box can be reached by the operator…
↓ then
Totally enclosed Hopper (doghouse) with Interlock Switch (mandatory)
↓ or
Sustained Manual Pressure Control (“hold-to-run” button) (mandatory)
↓ or
Special Extended Hopper (as shown above) (mandatory)
Thru-The-Wall Installation
If the bottom of a thru-the-wall Security Door is not 42″ high
↓ Then
Interlock Switch
↓ or
Sustained Manual Pressure Control (“hold-to-run” button)
Note: Interlock Switch is recommended for all Security Doors and is required in some states.
Dock Installation
If the is no 42″ high barrier between the operator and the charge box
↓ Then
Access Gate with Interlock Switch (mandatory)
↓ or
Sustained Manual Pressure Control (“hold-to-run” button) (mandatory)
↓ or
4-Sided Hopper (mandatory)
Walk-On / Drive-On Installation
If the operator must drive onto the compactor
↓ Then
And
Rear Feed Hopper (3 sided) with Access Gate with Interlock Switch (mandatory)
↓ or
Sustained Manual Pressure Control (“hold-to-run” button) (mandatory)
↓ or
Rear Feed Hopper (4 sided) (mandatory)
And
700# Treadplate (mandatory) with Hand & Toe Rails (mandatory)
↓ or
8000# Treadplate (mandatory) with Hand & Toe Rails (mandatory)
↓ And
Must be extended if compactor is not against dock (as shown above) (mandatory)
Cart Dumper Installation
If the dumper is installed with a compactor
↓ Then
Sustained Manual Pressure Control (“hold-to-run” button) (mandatory)
↓ And
Controls located outside area of operation (mandatory)
↓ And
Controls located in sight of area of operation (mandatory)
Suggested:
Guard Railing with Access Gate and Interlock Switch
Location of Emergency Stop
Stop Button must be located within three (3) feet (36 inches) of the Material Feed Area.
Note: Compactor must have Key Switch or other security device.
Location of Fused Disconnect
An Electrical Disconnect must be located within 50 feet, and in sight of, the Compactor Control Panel.
Hand & Toe Rail Design
Guard Railings for docks with walk-on ramps shall be located around the charging chamber opening. Guard railings and toe boards shall be provided on the sides of all walk-on ramps (in accordance with OSHA 1910.23).
Installer Labeling Requirements
A Label shall be affixed to the equipment.